Projects
Retail Stores
Energy Audit Completion Date = September - December 2023
Location = 11 sites across the United States
Area = 140,000 - 170,000 ft²
EUI = 109 - 200
Building Purpose = Retail store supplying refrigerated and non-refrigerated goods to hundreds of daily customers.
ECMs Discovered = 20 - 25
Annual Savings (Average) = 3.5 million kWh, 15k therms, 500 kGal, 900k kg CO2, and $650k
Hospital
Energy Audit Completion Date = November 2023
Location = North-East United States
Area = 510,000 ft²
EUI = 235
Building Purpose = Full service hospital for a small town.
ECMs Discovered = 25
Annual Savings = 8 million kWh, 27k therms, 300 kGal, 1 million kg CO2, and $800k
Energy Audit Completion Date = April 2022
Location = South America
Area = 450,000 ft²
EUI = 110
Building Purpose = Manufacturing industrial tools. Contained various high intensity machinery and processes.
ECMs Discovered = 8
Annual Savings = 1.5 million kWh, 6k kGal, 178k kg CO2, and $200k
International Manufacturing Plant
Hotel
Energy Audit Completion Date = June 2022
Location = South-East United States
Area = 150,000 ft²
EUI = 75
Building Purpose = Resort hotel with heated pool.
ECMs Discovered = 25
Annual Savings = 1.5 million kWh, 6k therms, 9k kGal, 600k kg CO2, and $300k
Energy Audit Completion Date = December 2024
Location = North-East United States
Area = 12,000 ft²
EUI = 96
Building Purpose = Place of worship with an attached rectory.
ECMs Discovered = 7
Annual Savings = 24k kWh, 2.5k therms (natural gas), 23 kGal, 20k kg CO2, and $9k
Office Building
Energy Audit Completion Date = December 2021
Location = North-East United States
Area = 280,000 ft²
EUI = 48
Building Purpose = High-rise office building housing several different companies.
ECMs Discovered = 14
Annual Savings = 800k kWh, 11k therms, 750 kGal, 350k kg CO2, and $200k
Sports Arena
Energy Audit Completion Date = March 2021
Location = North-East United States
Area = 700,000 ft²
EUI = 150
Building Purpose = Houses multiple different sporting events. Contained different HVAC systems to condition the various use types of the facility, including an ice rink.
ECMs Discovered = 24
Annual Savings = 12 million kWh, 20k therms, 1.5k kGal, 6 million kg CO2, and $3 million
Multifamily Residence
Energy Audit Completion Date = January 2025
Location = Central United States
Area = 300,000 ft²
Energy Usage Intensity (EUI) = 72
Building Purpose = High-rise multifamily residence with over 175 units.
Energy Conservation Measures (ECMs) Discovered = 12
Annual Savings = 2.5 million kWh (electricity), 2.4k kGal (water), 700k kg CO2 (emissions), and $250k (utility costs)
Church
Energy Audit Completion Date = May 2024
Location = 2 sites in Central United States
Area = 50,000 - 75,000 ft²
EUI = N/A
Building Purpose = Dock and storage facilities used for maintaining boats. Also contained recreational areas and restaurants.
ECMs Discovered = 6 - 11
Annual Savings (Average) = 800k kWh, 22k therms, 1.8k kGal, 537k kg CO2, and $175k